Abstract 

Introduction

Up to 20% of hospital patients will have pressure ulcers; more than half will be nosocomial and are associated with high treatment cost, increased morbidity, complaints and litigation. Consequently, patient safety programmes may include the provision of pressure-redistributing mattress replacements (PRM). However, despite the different functionality of PRMs, there is often little information to support clinical prescription; with some mattresses potentially unsuitable for a busy acute care environment: this is particularly true for mattresses which require manual adjustment each time the patient changes position.

Methods

A systematic prospective investigation of a new PRM was conducted over a 5-month period; following a convenience sample of high-risk hospital patients. The device automatically detects the angle of back rest, optimises cell inflation and reduces the risk of user error and sub-optimal support. Outcomes reported: ulcer prevention, healing, usability.

Results

A convenience sample of 60 patients were included; 39 (65%) had existing wounds. A single patient developed erythema to the sacrum (1.6%) while the majority of existing wounds (69%), including full thickness injury, improved or healed. The utility of the device was well received by staff and patients.

Conclusion

Although ideal, effectiveness studies (such as RCTs) are difficult to control in wound care and seldom reflect the natural challenges encountered in a busy hospital. By contrast the data arising from this pragmatic evaluation showed the mattress to be compatible with the care setting and also suitable for the vulnerability of the population and so provided the necessary information to inform subsequent clinical practice.

Keywords: Systematic evaluation, Pressure-redistributing support surface, Active therapy

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 The study was supported by the loan of equipment from ArjoHuntleigh; no other funding was provided.